傻大方


首页 > 知识库 > >

图表相关|回弹法检测泵送混凝土换算表[图表相关]


按关键词阅读: 回弹 图表相关 相关 图表 换算表 混凝土 检测

1、附录B 测区泵送混凝土强度换算表表B 测区泵送混凝土强度换算表平均回弹值Rm测区混凝土强度换算值 (MPa)平均碳化深度值dm(mm)0.00.51.01.52.02.53.03.54.04.55.05.5618.610.018.810.210.019.010.410.210.019.210.610.410.210.019.410.910.710.410.210.019.611.110.910.610.410.210.019.811.311.110.910.610.410.210.020.011.511.311.110.910.610.410.210.020.211.811.511.311.1 。

2、10.910.610.410.210.020.412.011.711.511.311.110.810.610.410.210.020.612.212.011.711.511.311.010.810.610.410.210.020.812.412.212.011.711.511.311.010.810.610.410.210.021.012.712.412.211.911.711.511.211.010.810.610.410.210.021.212.912.712.412.211.911.711.511.211.010.810.610.410.221.413.112.912.612.412.1 。

3、11.911.711.411.211.010.810.610.321.613.413.112.912.612.412.111.911.611.411.211.010.710.521.813.613.413.112.812.612.312.111.911.611.411.210.910.722.013.913.613.313.112.812.612.312.111.811.611.411.110.922.214.113.813.613.313.012.812.512.312.011.811.611.311.122.414.414.113.813.513.313.012.712.512.212.0 。

【图表相关|回弹法检测泵送混凝土换算表[图表相关]】4、11.811.511.322.614.614.314.013.813.513.213.012.712.512.212.011.711.522.814.914.614.314.013.713.513.212.912.712.412.211.911.723.015.114.814.514.214.013.713.413.112.912.612.412.111.923.215.415.114.814.514.213.913.613.413.112.812.612.312.123.415.615.315.014.714.414.113.913.613.313.112.812.612.323.615.9 。

5、15.615.315.014.714.414.113.813.513.313.012.812.523.816.215.815.515.214.914.614.314.113.813.513.213.012.724.016.416.115.815.515.214.914.614.314.013.713.513.212.924.216.716.416.015.715.415.114.814.514.213.913.713.413.124.417.016.616.316.015.715.315.014.714.514.213.913.613.324.617.216.916.516.215.915.6 。

6、15.315.014.714.414.113.813.624.817.517.116.816.516.215.815.515.214.914.614.314.113.825.017.817.417.116.716.416.115.815.515.214.914.614.314.0平均回弹值Rm测区混凝土强度换算值 (MPa)平均碳化深度值dm(mm)0.00.51.01.52.02.53.03.54.04.55.05.5625.218.017.717.317.016.716.316.015.715.415.114.814.514.225.418.318.017.617.316.916.616. 。

7、315.915.615.315.014.714.425.618.618.217.917.517.216.816.516.215.915.615.214.914.725.818.918.518.217.817.417.116.816.416.115.815.515.214.926.019.218.818.418.117.717.417.016.716.316.015.715.415.126.219.519.118.718.318.017.617.316.916.616.315.915.615.326.419.819.419.018.618.217.917.517.216.816.516.215. 。

8、915.626.620.019.619.318.918.518.117.817.417.116.816.416.115.826.820.319.919.519.218.818.418.017.717.317.016.716.316.027.020.620.219.819.419.118.718.317.917.617.216.916.616.227.220.920.520.119.719.318.918.618.217.817.517.116.816.527.421.220.820.420.019.619.218.818.518.117.717.417.116.727.621.521.120. 。

9、720.319.919.519.118.718.418.017.617.317.027.821.821.421.020.620.219.819.419.018.618.317.917.517.228.022.121.721.320.920.420.019.619.318.918.518.117.817.428.222.422.021.621.120.720.319.919.519.118.818.418.017.728.422.822.321.921.421.020.620.219.819.419.018.618.317.928.623.122.622.221.721.320.920.520. 。

10、119.719.318.918.518.228.823.422.922.522.021.621.220.720.319.919.519.218.818.429.023.723.222.822.321.921.521.020.620.219.819.419.018.729.224.023.523.122.622.221.721.320.920.520.119.719.318.929.424.323.923.422.922.522.021.621.220.820.319.919.519.229.624.724.223.723.222.822.321.921.421.020.620.219.819. 。

11、429.825.024.524.023.523.122.622.221.721.320.920.520.119.730.025.324.824.323.823.422.922.522.021.621.220.720.319.930.225.625.124.624.223.723.222.822.321.921.421.020.620.230.426.025.525.024.524.023.523.022.622.121.721.320.920.430.626.325.825.324.824.323.823.322.922.422.021.621.120.730.826.626.125.625. 。

12、124.624.123.623.222.722.321.821.421.031.027.026.425.925.424.924.423.923.523.022.522.121.721.231.227.326.826.225.725.224.724.223.823.322.822.421.921.531.427.727.126.626.025.525.024.524.123.623.122.722.221.831.628.027.426.926.425.925.324.824.423.923.422.922.522.031.828.327.827.226.726.225.725.124.724. 。

13、223.723.222.822.332.028.728.127.627.026.526.025.525.024.524.023.523.022.632.229.028.527.927.426.826.325.825.324.824.323.823.322.9平均回弹值Rm测区混凝土强度换算值 (MPa)平均碳化深度值dm(mm)0.00.51.01.52.02.53.03.54.04.55.05.5632.429.428.828.227.727.126.626.125.625.124.624.123.623.132.629.729.228.628.027.526.926.425.925.424 。

14、.924.423.923.432.830.129.528.928.327.827.226.726.225.725.224.724.223.733.030.429.829.328.728.127.627.026.526.025.525.024.524.033.230.830.229.629.028.427.927.326.826.325.825.224.724.333.431.230.630.029.428.828.227.727.126.626.125.525.024.533.631.530.930.329.729.128.528.027.426.926.425.825.324.833.831 。

15、.931.330.730.029.528.928.327.727.226.726.125.625.134.032.331.631.030.429.829.228.628.127.527.026.425.925.434.232.632.031.430.730.129.529.028.427.827.326.726.225.734.433.032.431.731.130.529.929.328.728.127.627.026.526.034.633.432.732.131.430.830.229.629.028.527.927.426.826.334.833.833.132.431.831.230 。

16、.630.029.428.828.227.727.126.635.034.133.532.832.231.530.930.329.729.128.528.027.426.935.234.533.833.232.531.931.230.630.029.428.828.327.727.235.434.934.233.532.932.231.631.030.429.829.228.628.027.535.635.334.633.933.232.631.931.330.730.129.528.928.327.835.835.735.034.333.632.932.331.631.030.429.829 。